Solarbio BCA kit za test proteina 50T

$50.00

Dostava USD 45 - Besplatno preko USD 300

DTE je kineska platforma za e-trgovinu specijalizirana za online prodaju molekularnog testiranja, ELISA, i srodni proizvodi.

  • Proizvođač: Vodeći kineski brendovi
  • dostava: Ubrzana isporuka FedExom izravno iz tvornica
  • Ispunjava uvjete za povrat ili zamjenu unutar 30 dana
  • Metode Plačanja: Osigurajte PayPal ili kreditnu karticu.

Opis

The BCA (Bicinchoninic Acid) Protein Assay Kit is a widely utilized colorimetric method for the quantification of protein concentrations in a sample. This assay relies on the reduction of Cu^2+ ions to Cu^1+ by proteins under alkaline conditions, forming a purple-colored complex with bicinchoninic acid. The intensity of the color is directly proportional to the protein concentration, enabling accurate quantification.

Here is a step-by-step guide on how to use a BCA protein Komplet za analizu:

Materials Required:

  1. BCA kit za ispitivanje proteina
  2. Protein standards (bovine serum albumin is commonly used)
  3. Sample containing unknown protein concentrations
  4. Microplate or cuvettes
  5. Micropipettes and tips
  6. Microplate reader or spectrophotometer
  7. Destilirana voda

Postupak:

  1. Preparation of Protein Standards:
    • Prepare a series of protein standards with known concentrations. These standards will be used to create a standard curve for quantification. Common concentrations are 0, 0.125, 0.25, 0.5, 0.75, i 1.0 mg/ml.
  2. Preparation of Sample:
    • Dilute your protein sample to a suitable concentration within the linear range of the assay. If needed, you may need to perform a preliminary dilution to ensure that the sample falls within the standard curve.
  3. Preparation of BCA Working Reagent:
    • Mix BCA Reagent A and BCA Reagent B in a 50:1 ratio (typically provided in the kit). Ensure thorough mixing.
  4. Addition of Standards and Sample:
    • Pipette aliquots of the protein standards and the sample into separate wells of a microplate. Each standard and sample should be run in duplicate or triplicate.
  5. Addition of BCA Working Reagent:
    • Add an appropriate volume of the BCA Working Reagent to each well containing standards and samples. Temeljito promiješajte.
  6. Inkubacija:
    • Incubate the microplate at an appropriate temperature (typically 37°C) za 30 minutes to allow the color reaction to occur.
  7. Mjerenje:
    • Measure the absorbance of each well at 562 nm using a microplate reader or spectrophotometer.
  8. Creation of Standard Curve:
    • Plot the absorbance values of the standards against their known concentrations to create a standard curve.
  9. Quantification of Sample:
    • Use the standard curve to determine the protein concentration of your sample based on its absorbance.
  10. Data Analysis:
    • Calculate the concentration of protein in the sample based on the standard curve. Most microplate readers have software that can assist in this analysis.

Recenzije kupaca o solarbio proizvodima za referencu

Dodatne informacije

Težina 0.65 kg

Recenzije (0)

Recenzije

Još nema recenzija.

Budite prvi koji će recenzirati “Solarbio BCA kit za test proteina 50T”

Vaša email adresa neće biti objavljena. obavezna polja su označena *


Prilog

Košarica
Pomaknite se na vrh