HiPure DNA Clean Up 96 Kit uses proprietary chemistry and HiPure technology to recover DNA Fragments between 60bp-10kbp with yields exceeding 80%. DNA is suitable for ligations, PCR, sequencing, restriction digestion, or various labeling reactions. In addition, this kit can be also used to recover DNA directly from enzymatic reactions such as PCR and enzyme digestion reactions.
Details
Specifications
Features | Specifications |
Main Functions | Recover DNA fragments between 60bp-10kbp from PCR, Reactions, crude DNA using 96 well Bind Plate |
Applications | PCR, sequencing, labeling reactions, ligations and restriction digestion, etc. |
Purification method | 96 well Bind Plate |
Purification technology | Silica technology |
Process method | Manual (centrifugation or vacuum) |
Sample type | PCR product, enzymatic reaction |
Sample amount | <span “=”” style=”outline: 0px; box-sizing: border-box; font-size: 16px;”>Appropriate |
Recovery | <span “=”” style=”outline: 0px; box-sizing: border-box; font-size: 16px;”>≥80% |
Elution volume | <span “=”” style=”outline: 0px; box-sizing: border-box; font-size: 16px;”>≥75μl |
Time per run | <span “=”” style=”outline: 0px; box-sizing: border-box; font-size: 16px;”>≤60 minutes |
Liquid carrying volume per column | 800µl |
Binding yield of column | 20µg |
Principle
The HiPure system uses a simple bind-wash-elute procedure. Gel slices are dissolved in a buffer containing a pH indicator, allowing easy determination of the optimal pH for DNA binding, and the mixture is applied to the column. Nucleic acids adsorb to the silica-gel membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in subsequent applications.
Advantages
- High recovery efficiency – ≥80% DNA recovery
- Fast – isolation can be completed in 60 minutes
Kit Contents
Contents | D212201 | D212202 | D212203 |
Purification Times | 1 x 96 Preps | 4 x 96 Preps | 20 x 96 Preps |
Buffer GDP | 120 ml | 400 ml | 4 x 400 ml |
Buffer DW2 | 20 ml | 100 ml | 3 x 100 ml |
Elution Buffer | 20 ml | 20 ml | 30 ml |
HiPure DNA Plate | 1 | 4 | 20 |
2.2ml Collection Plate | 1 | 4 | 20 |
1.6 ml Collection Plate | 1 | 4 | 20 |
0.8 ml Collection Plate | 1 | 4 | 20 |
Storage and Stability
The Kit can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions. If any precipitates form in the buffers, warm at 37℃ to dissolve.
Reviews