Introduction
- HiPure Columns by Magen Biotech:
- Prepared using high-quality glass fiber filter membrane.
- Production processes include membrane cutting, release, ring pressing, gland, and weighing.
- Characteristics: long-term stability and high binding capacity.
- Experiments demonstrate unchanged binding capacity and efficiency when stored at room temperature for 4 années.
- Nucleic Acid Columns Series:
- Based on imported glass fiber membranes (GF/B, GF/D, GF/F).
- Production processes are strictly controlled, including material selection, injection molding, and membrane packing.
- Ensures extremely high adsorption capacity and long-term stability.
- Varieties available, with binding rate unchanged when stored at room temperature for 4 années.
Caractéristiques
Caractéristiques | Caractéristiques |
---|---|
Application recommandée | Micronucleic acid extraction and purification, virus total nucleic acid extraction |
Conditions de conservation | Température ambiante |
La stabilité | Jusqu'à 4 années |
Filter membrane | High-quality glass fiber filter GF/F, 2 layers |
Membrane aperture | 0.7 µm |
Maximum binding yield of plasmid | 5 µg |
Maximum yield of alcohol-mediated Binding | 20 µg |
Single liquid carrying capacity of column | >700 µl |
Minimum elution volume | >10 µl |
Withstand centrifugal force | 12,000 x g |
Centrifuger | Small high-speed centrifuge (2ml) |
Adsorption Mechanism
DNA/RNA Binding Process:
- Affinity to Glass Fibers:
- Based on the negatively charged DNA skeleton, it exhibits a high affinity for positively charged glass fibers.
- Interaction with Silica Gel:
- In high salt and ethanol solutions, DNA/RNA binds to glass fibers and interacts with the hydrophilic matrix on silica through hydrogen bonds.
- This interaction results in tight binding of DNA/RNA to the silica gel membrane.
- Pollutant Removal:
- Washing the solution removes all pollutants.
- At high salt concentrations, nucleic acids selectively bind to the silica gel membrane, while other pollutants, primarily proteins, are removed by membrane washing.
Guide d'achat
Numéro d'article. | Nom du produit | Membrane type/number of layers | Collection tubes | ADN plasmidique binding capacity (Physical adsorption) | gDNA/RNA binding capacity (Alcohol-mediated adsorption) | Minimum Elution volume | Liquid volume capacity |
C13010 | Colonne nano d'ADN HiPure | 2 layers GF/F | 2ml without cap | 5mg | 20µg | 10µl | 700mje |
C13011 | HiPure DNA Micro Column | 3 layers GF/F | 2ml without cap | 10mg | 50µg | 15µl | 700mje |
C13100 | HiPure DNA Mini Column I | 2 layers GF/B | 2ml without cap | 15mg | 100µg | 30µl | 700mje |
C13110 | HiPure DNA Mini Column II | 4 layers GF/B | 2ml without cap | 35mg | 200µg | 50µl | 800mje |
C13111 | HiPure RNA Mini Column | 3 layers GF/B | 2ml without cap | 30mg | 200µg | 30µl | 800mje |
C13112 | HiPure Viral Mini Column | 3 layers GF/F | 2ml without cap | 30mg | 200µg | 30µl | 800mje |
C13113 | HiPure CFDNA Mini Column | 3 layers GF/F,1 layer GF/B | 2ml without cap | 30mg | 200µg | 30µl | 800mje |
C13120 | HiPure DNA Midi Column | 4 layers GF/B | 15ml Centrifuge tube | 125mg | 1mg | 500µl | 4ml |
C13121 | HiPure DNA Midi Column III | 8 layers GF/B | 15ml Centrifuge tube | 250mg | 1mg | 500µl | 4ml |
C13122 | HiPure DNA Maxi Column | 4 layers GF/B | 50ml Centrifuge tube | 500mg | 5mg | 1000µl | 20ml |
C13123 | HiPure DNA Maxi Column III | 8 layers GF/B | 50ml Centrifuge tube | 1mg | 5mg | 1000µl | 20ml |
C13124 | HiPure DNA Maxi Column C | 8 layers GF/B | 50ml high speed Centrifuge tube | 1mg | 5mg | 700µl | 12ml |
C13130 | HiPure DNA Plate | 2 layers GF/F | 1.6ml Plaque | 30mg | 100µg | 80µl | 900µl |
C13131 | HiPure gDNA Plate | 2 layers GF/B | 1.6ml Plaque | 30mg | 100µg | 80µl | 900µl |
Note: GF/B pore size is for 1.0μM glass fiber membrane; GF/F pore size is for 0.7μm glass fiber membrane.
Commentaires