Introduction
- HiPure Columns by Magen Biotech:
- Prepared using high-quality glass fiber filter membrane.
- Production processes include membrane cutting, release, ring pressing, gland, and weighing.
- Characteristics: long-term stability and high binding capacity.
- Experiments demonstrate unchanged binding capacity and efficiency when stored at room temperature for 4 years.
- Nucleic Acid Columns Series:
- Based on imported glass fiber membranes (GF/B, GF/D, GF/F).
- Production processes are strictly controlled, including material selection, injection molding, and membrane packing.
- Ensures extremely high adsorption capacity and long-term stability.
- Varieties available, with binding rate unchanged when stored at room temperature for 4 years.
Specifications
Features | Specifications |
---|---|
Recommended application | Micronucleic acid extraction and purification, virus total nucleic acid extraction |
Preservation conditions | Room temperature |
Stability | Up to 4 years |
Filter membrane | High-quality glass fiber filter GF/F, 2 layers |
Membrane aperture | 0.7 μm |
Maximum binding yield of plasmid | 5 μg |
Maximum yield of alcohol-mediated Binding | 20 μg |
Single liquid carrying capacity of column | >700 μl |
Minimum elution volume | >10 μl |
Withstand centrifugal force | 12,000 x g |
Centrifuge | Small high-speed centrifuge (2ml) |
Adsorption Mechanism
DNA/RNA Binding Process:
- Affinity to Glass Fibers:
- Based on the negatively charged DNA skeleton, it exhibits a high affinity for positively charged glass fibers.
- Interaction with Silica Gel:
- In high salt and ethanol solutions, DNA/RNA binds to glass fibers and interacts with the hydrophilic matrix on silica through hydrogen bonds.
- This interaction results in tight binding of DNA/RNA to the silica gel membrane.
- Pollutant Removal:
- Washing the solution removes all pollutants.
- At high salt concentrations, nucleic acids selectively bind to the silica gel membrane, while other pollutants, primarily proteins, are removed by membrane washing.
Purchase Guide
Item No. | Product Name | Membrane type/number of layers | Collection tubes | Plasmid DNA binding capacity (Physical adsorption) | gDNA/RNA binding capacity (Alcohol-mediated adsorption) | Minimum Elution volume | Liquid volume capacity |
C13010 | HiPure DNA Nano Column | 2 layers GF/F | 2ml without cap | 5μg | 20μg | 10μl | 700μl |
C13011 | HiPure DNA Micro Column | 3 layers GF/F | 2ml without cap | 10μg | 50μg | 15μl | 700μl |
C13100 | HiPure DNA Mini Column I | 2 layers GF/B | 2ml without cap | 15μg | 100μg | 30μl | 700μl |
C13110 | HiPure DNA Mini Column II | 4 layers GF/B | 2ml without cap | 35μg | 200μg | 50μl | 800μl |
C13111 | HiPure RNA Mini Column | 3 layers GF/B | 2ml without cap | 30μg | 200μg | 30μl | 800μl |
C13112 | HiPure Viral Mini Column | 3 layers GF/F | 2ml without cap | 30μg | 200μg | 30μl | 800μl |
C13113 | HiPure CFDNA Mini Column | 3 layers GF/F,1 layer GF/B | 2ml without cap | 30μg | 200μg | 30μl | 800μl |
C13120 | HiPure DNA Midi Column | 4 layers GF/B | 15ml Centrifuge tube | 125μg | 1mg | 500μl | 4ml |
C13121 | HiPure DNA Midi Column III | 8 layers GF/B | 15ml Centrifuge tube | 250μg | 1mg | 500μl | 4ml |
C13122 | HiPure DNA Maxi Column | 4 layers GF/B | 50ml Centrifuge tube | 500μg | 5mg | 1000μl | 20ml |
C13123 | HiPure DNA Maxi Column III | 8 layers GF/B | 50ml Centrifuge tube | 1mg | 5mg | 1000μl | 20ml |
C13124 | HiPure DNA Maxi Column C | 8 layers GF/B | 50ml high speed Centrifuge tube | 1mg | 5mg | 700μl | 12ml |
C13130 | HiPure DNA Plate | 2 layers GF/F | 1.6ml Plate | 30μg | 100μg | 80μl | 900μl |
C13131 | HiPure gDNA Plate | 2 layers GF/B | 1.6ml Plate | 30μg | 100μg | 80μl | 900μl |
Note: GF/B pore size is for 1.0μM glass fiber membrane; GF/F pore size is for 0.7μm glass fiber membrane.