Specifications
Features | Specifications |
Principle | Extraction by magnetic beads |
Throughput | 1-96 samples and a single sample |
Process Volume | 20-1000 μl |
Sample Volume | ≤500 μl |
Plate types | 96-deep well plate |
Magnetic Rods | 96 rods |
Purification accuracy | 102 copies/ml samples positive rate>98% |
Stability | Cv<1% |
Heating function | Heating holders are provided at 1st and 6th lines (can be customized) |
Mix by vortex | 11 different mixing modes (1 – 10 speed levels) |
Magnetic bead size | >100 nm |
Reagents | An open platform for magnetic bead methods |
User interface | 7-inch color touchscreen |
Storage capacity | Up to 1000 programs |
Protocol management | Create, edit, delete, copy, output by USB |
UV light | Yes |
Exhaust Mode | Induced fan |
Running time | 1-60 minutes(Depends on program setting) |
Weight | 55 KG |
Dimensions | 600mm X 500mm X 500mm |
Principle
This system offers a fully automated solution for nucleic acid extraction using magnetic beads:
- Automated Processing: Magnetic rods precisely control the movement of beads and disposable tips, streamlining sample mixing, lysis, nucleic acid binding, washing, and elution.
- High-Quality Results: The process delivers high-quality nucleic acids suitable for various downstream applications.
- Efficiency: Magnetic bead separation allows for efficient extraction with minimal processing time.
- Stable Results: The automated system ensures consistent and reliable results across samples.
- Easy Operation: Single-tube consumables simplify the workflow and minimize user interaction.
- Flexibility: This method offers a high level of automation while maintaining flexibility for various sample types.
Advantages
- Automated & High throughput – full automation, up to 96 samples can be processed at one time, 4-5 times more efficient than manual method.
- High efficiency – the optimization of full magnetic rod and amplitude adjustment technology can easily deal with various small magnetic beads to achieve no hanging or residue.
- Standard – multiple running programs can be edited as needed and a large storage core is provided to ensure the unity of experimental conditions.
- Intelligent – flexible throughput can meet different needs of extraction while the unique UL design of the control panel can display the operating parameters at one time, easy to understand and operate.
- Precise temperature – full contact between the deep well plates and heating modules, leads to a precise and stable temperature within each well, resulting in a high efficiency of sample lysis and nucleic acid elution.
- Safe-disposable tips and built-in UV radiation lower the safety risk of operation and avoid aerosol contamination between each run.
Purchase Guide
Item No. | Consumables | Extraction mode | Plate/Strip amount | Hole/Plate position | Sample amount | Sample volume | Process Volume |
MagMix 16 | 96 well plate | Single plate, 16 samples/plate | 1 plate | 6 hole position | 16 | <800μl | 1ml |
MagMix 32 | 96 well plate | Single plate, 16 samples/plate | 2 plates | 6 hole position | 32 | <1ml | 1ml |
MagMix 48 | 96 well plate | Single plate, 16 samples/plate | 3 plates | 6 hole position | 48 | <500μl | 1ml |
MagMix 96 | 96 well plate | Multiple plates, 96 samples/plate | 6 plates | 6 hole position | 96 | <500μl | 1ml |
MagRotex 8 | Reagent strip | Reagent strip | 8 strips | 7 hole position | 8 | 0.2-1ml | 4ml |
MagRotex 32 | Reagent strip | Reagent strip | 32 strips | 7 hole position | 32 | 0.2-4ml | 4ml |
MagMix 32B | 48 well plate | Single plate, 8 samples/plate | 4 plates | 6 hole position | 32 | <750μl | 1.5ml |
MagMix 48B | 48 well plate | Multiple plates, 48 samples/plate | 6 plates | 6 hole position | 48 | <750μl | 1.5ml |
MagMix 12 | 24 well plate | Single plate, 4 samples/plate | 3 plates | 6 hole position | 12 | <2ml | 5ml |
MagMix 24 | 24 well plate | Multiple plates, 24 samples/plate | 6 plates | 6 hole position | 24 | <2ml | 5ml |
MagRotex 24 | Reagent strip | Reagent strip | 24 strips | 6 hole position | 24 | 2ml-4ml | 7ml |
MagRotex 24 Plus | Reagent strip | Reagent strip | 24 strips | 9 hole position | 24 | 2ml-9ml | 10ml |
Reviews
There are no reviews yet.