Migi-Bio Dogs Cats Rapid Test Immunofluorescence Analyzer FIA-680

Original price was: $1,200.00.Current price is: $1,099.00.

Shipping USD 45 - Free over USD 300

DTE is a China-based e-commerce platform specializing in online sales of molecular testing, ELISA, and related products.

  • Manufacturer: Leading Chinese brands
  • Shipping: Expedited FedEx shipping directly from the factories
  • Eligible for return or replacement within 30 days
  • Payment Methods: Secure PayPal or credit card.

Description

Contact us for the equipment and test kits combo wholesale


Product Overview

Immunofluorescence chromatography technology uses polystyrene fluorescent microspheres as a biomarker in which lanthanum europium (Eu) was embedded. The technology has high sensitivity and good specificity because europium has two special fluorescence properties of large stokes shift and long fluorescence lifetime which have strong fluorescence intensity and can minimize the interference of background fluorescence.

Immunofluorescence Analyzer

Attribute Specification
Product model FIA-680 Vet
Channel 1 channel
Display screen 7-inch color LCD touchscreen
Operating system Android intelligent operating system
Result output Built-in thermal printer or WIFI transfer to computer
Working environment Temperature: 5℃-40℃<br>Humidity: 10-80%
Storage capacity 255 items, 100,000 pieces of data
Fluorescent excitation/emission wavelength 365/610 (nm)
Port USB, WIFI, RS232

Operation Guide for FIA680 VET

instruction FA680 Vet

Pet Items and Introduction

Category Product Name Sample Type Sample Volume Loading Volume Incubation Time
Inflammation cCRP Whole blood (WB) / Serum / Plasma 10μl 100μl 3min
fSAA Serum / Plasma 5min
cPL / fPL Serum / Plasma 50μl 15min
Pathogen CDV-Ag / FHV-Ag / FCV-Ag Nasopharyngeal / Ocular swab 1/2~2/3 Swab 10min
CPV-Ag / CCV-Ag Rectal swab 10min
FPV-Ag / FCoV-Ag Rectal swab 10min
FeLV-Ag Serum / Plasma 20μl
Antibody CPV-Ab / CDV-Ab Serum / Plasma
CAV-Ab / cLSH-Ab Serum / Plasma
cTOXO-Ab / FPV-Ab / FHV-Ab / FCV-Ab Serum / Plasma 20μl
FIV-Ab 10μl
Heart failure cNT-proBNP / fNT-proBNP 50μl 15min
Renal failure cCys C / fCys C 10min
Breeding cProgesterone / cRelaxin
Other cCortisol / cTSH
cTT4 / fTT4 2min + 10min

Product and Test Menu of FIA680 Vet

FAQ

Q&A: what is the principle of immunofluorescence chromatography?

It is a novel membrane detection technology based on antigen-antibody specific immune response. Using europium polystyrene fluorescent microspheres as a biomarker. Labeled antibody or antigen with fluorescent microspheres is fixed on the binding pad and the analyte is moved on the chromatographic strip through capillary action. For large molecular antigens (proteins, viruses, pathogens, etc.) with multiple antigenic epitopes, a double-antibody “sandwich” type is usually used.

Q&A: Why can immunofluorescence chromatography quantify the sample concentration?

The immunofluorescence analyzer scans the fluorescence signal of the T (detection) line and the C (control) line of the detection card and converts the fluorescence signal value into the sample concentration according to the standard curve in the lD card to achieve the sample concentration.

Q&A: What’s the difference between standard and quick tests?

The standard test is used for a single sample, click “Standard Test” and “Start Test”, after In-machine incubation, and detection is automatic. The rapid test is suitable for multiple samples and out-of-machine incubation, click “Quick Test” and “Start Test”, the detection will begin immediately.

Q&A: How long does the test?

The time is about 11 minutes: about 30 seconds for dilution and sample addition, and the immune reaction time (incubation) of items is generally 10 minutes. But the incubation time of cCRP is 3 minutes, fSAA is 5 minutes.

Q&A: How many tests is the detection throughput?

“Standard Test”: single channel FIA680 is 5 tests per hour and six channels FIA880 is 30 tests per hour.

“Quick Test”: single channel FIA680 is 200 tests per hour six channels FIA880 is 300 tests per hour.

Product and Test Menu of FIA680 Vet

Category Item Sample Type Sample Volume Loading Volume Incubation Time Unit Detection Range Result  Interpretation
Inflammation cCRP WB / Serum / Plasma 10μl 100μl 3min      mg/L 5.0 ~300 ≤10(-)/ 10 ~30( +/ 30 ~100( ++)/ > 100( +++)
fSAA WB / Serum / Plasma 10μl 100μl 5min      mg/L 5.0 ~300 ≤10(-)/ 10 ~50( +)/ 50 ~150( ++/ > 150( +++)
cPL Serum / Plasma 50μl 100μl 15min      ng/ml 50 ~3200 Risk  (  ≤100 Low/  100 ~300 medium/  >300High )
fPL Serum / Plasma 50μl 100μl 15min      ng/ml 2.0 ~224 Risk  (  ≤3.5 Low/  3.5 ~5.3 Medium/ >5.3High )
Pathogen CDV-Ag Nasopharyngeal /

Ocular swab

Swab 100μl 10min      Tu/ml 4.0 ~640 ≤8(-)/ 8~12(±)  / 12 ~30( +)/ 30 ~100( ++)/ >100( +++)
CPV-Ag Rectal swab Swab 100μl 10min      Tu/ml 4.0~640 ≤8(-)/ 8~15(±)  /15~40( +)/ 40 ~200( ++)/ >200( +++)
CCV-Ag Rectal swab Swab 100μl 10min      Tu/ml 5.0 ~640 ≤10(-)/ 10~12(±)  /12 ~20( +)   / 20 ~80( ++/ >80( +++)
FPV-Ag Rectal swab Swab 100μl 10min      Tu/ml 4.0 ~640 ≤8(-)/ 8~15(±)  /15 ~40( +)/ 40 ~200( ++)/ >200( +++)
FHV-Ag Nasopharyngeal /

Ocular swab

Swab 100μl 10min      Tu/ml 5.0 ~640 ≤10(-)/10~13(±)  /13 ~25( +)/ 25 ~100( ++/ >100( +++)
FCV-Ag Nasopharyngeal /

Ocular swab

Swab 100μl 10min      Tu/ml 5.0 ~640 ≤10(-)   /10~14(±)  /14≤30( +)/ 30 ~150( ++)   />150( +++)
FCoV-Ag Rectal  swab Swab 100μl 10min      Tu/ml 5.0 ~320 ≤10(-/ 10~12(±)  /12 ~20( +)/ 20 ~80( ++)/ >80( +++)
FeLV-Ag Serum / Plasma 20μl 100μl 10min      Tu/ml 5.0 ~320 ≤10(-)/ 10~13(±)  /13 ~25( +)/ 25 ~100( ++/ >100( +++)
Antibody CPV-Ab Serum / Plasma 20μl 100μl 10min      Tu/ml 4.5 ~640 ≤9( L0)/ 9 ~50( L1)/50 ~150( L2) /150 ~300( L3)/ 300 ~500( L4)/ 500( L5)
CDV-Ab Serum / Plasma 20μl 100μl 10min      Tu/ml 5.0 ~640 ≤10( L0)   / 10 ~20( L1)   / 20 ~50( L2)/ 50 ~100( L3)/ 100 ~200( L4)   /  >200( L5)
CAV-Ab Serum / Plasma 20μl 100μl 10min      Tu/ml 4.0 ~640 ≤8( L0)/ 8 ~18( L1)/ 18~40   ( L2) 40 ~80( L3)/ 80 ~160( L4)/>  160( L5)
cLSH-Ab Serum / Plasma 20μl 100μl 10min      Tu/ml 3.0 ~320 ≤6.0(-)/6 ~12  ( ±)  /12 ~25( +) 25 ~100( ++)/  >100( +++)
cTOXO-Ab Serum / Plasma 50μl 100μl 10min      IU/mL 2.5 ~320 ≤5(-)/ 5 ~10  ( ±)   /10 ~25( +) 25 ~100( ++)/ >100( +++)
FPV-Ab Serum / Plasma 20μl 100μl 10min      Tu/ml 4.5 ~640 ≤9( L0)/ 9 ~50( L1)/50 ~150( L2) 150 ~300( L3)/ 300 ~500( L4)/ >500( L5)
FHV-Ab Serum / Plasma 20μl 100μl 10min      Tu/ml 5.0 ~640 ≤10( L0)/10 ~15( L1)/15~45( L2)45 ~100( L3)/ 100 ~150( L4)/ >150( L5)
FCV-Ab Serum / Plasma 20μl 100μl 10min      Tu/ml 5.0 ~640 ≤10(   L0)/10 ~30(  L1)/30 ~90(  L2)90 ~200(  L3)/ 200 ~300(  L4)/ >300(  L5)
F IV-Ab Serum / Plasma 10μl 100μl 10min      Tu/ml 4.5 ~320 ≤9(-)/9 ~11  ( ±)  /11 ~20( +)20 ~100( ++/  >100( +++)
FPV/ FHV/ FCV

Ab

Serum / Plasma 20μl 100μl 10min      Tu/ml CPV ~Ab 4.5~640

CDV ~Ab 5.0~640

CAV ~Ab  4.0 ~640

Refer to the reference range of single-card
CPV/ CDV/ CAV

Ab

Serum / Plasma 20μl 100μl 10min      Tu/ml FPV ~Ab 4.5~640

FHV ~Ab 5.0~640

FCV ~Ab 5.0~640

Refer to the reference range of single-card
Heart failure cNT-proBNP Serum / Plasma 50μl 100μl 15min     pmol/L 450 ~10000 ≤900( Normal)/ 900-1800( Dubious)/>1800(High risk)
fNT-proBNP Serum / Plasma 50μl 100μl 15min     pmol/L 50 ~1600 ≤100 Normal   >100 High risk
Renal failure cCys C Serum / Plasma 50μl 100μl 10min mg/ dL 3.0 ~ 34 <12(-)/ 12-15( +)/ >15( ++)
fCys C Serum / Plasma 50μl 100μl 10min mg/ dL 3.5 ~ 50 <7(-)/ 7-10( +)/ >10( ++)
Breeding cProgesterone Serum / Plasma 50μl 100μl 10min     ng/ml 1.0 ~50 ≤1.0( Non-estrus phase/ 1 ~5( Preovulation phase)/ 5 ~10( Oviposit phase)/ 10 ~20

(The best potential fertility phase)/

> 20( Ootid senescence  phase )

cRelaxin Serum / Plasma 50μl 100μl 10min     ng/ml 0.5 ~40 Leve  ( ≤3.0 Normal/>3.0  High)
Other cTT4 Serum / Plasma 50μl 100μl 2min+10min     nmol/L 5.0 ~960 ≤15 Low/ 15~60 Normal/ >60High
fTT4 Serum / Plasma 50μl 100μl 2min+10min     nmol/L 5.0 ~960 ≤15 Low/ 15~50 Normal/>50High
cTSH Serum / Plasma 50μl 100μl 10min     mIu/L 9.0 ~600 Level  ( ≤37 Normal/>37High )
cCortisol Serum / Plasma 50μl 100μl 10min     nmol/L 5.0 ~640 Level  ( ≤10Low/ 10~100 Normal>100High )

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Migi-Bio Dogs Cats Rapid Test Immunofluorescence Analyzer FIA-680”

Your email address will not be published. Required fields are marked *


Attachment

Shopping Cart
Scroll to Top